The boiler adopts advanced design concept and divides the boiler into multiple unit groups(one set of 128KW)…
Learn MoreThe Boiler adopts a more environmental friendly combustion mode-------pre-mixed combustion system. Fuel…
Learn MoreThe new and deep coupling technology of combustion and heat transfer breaks the limitation of burner,…
Learn MoreThe boiler adopts a new and environmental-friendly combustion mode------pre-mixed combustion. Gas and…
Learn MoreChina integrated two-pass wetback fire tube boiler is an ideal choice for all industrial and commercial…
Learn MoreAfter years’ data accumulation from our users, the wet back design has proven to give much longer useful…
Learn MoreLarge boiler capacities are often given in lbs of steam evaporated per hour under specified steam conditions. BTU - British Thermal Units Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour.
Get a quoteUsed Water Tube Package Boilers For Sale | Perry Videx
Get a quoteA boiler generates 5000 kg of steam per hour at 1.8 MN/m2. The steam temperature is 325 oC and the feedwater temperature is 49.4 oC. The efficiency of the boiler plant is 80% when using oil of calorific value 45,500 kJ/kg. The steam generated is supplied to a 2
Get a quote2015/3/17 · 5.866 kJ/kg/K Saturated 1.00 Energy Flow 50,710 Boiler Blowdown Rate 3.3 % Boiler Energy 42,104 Combustion Efficiency 66.9 % Fuel Energy 62,935
Get a quote1.7.3 Test Conditions and Precautions for Indirect Method Testing A) The efficiency test does not account for: Ł Standby losses.Efficiency test is to be carried out, when the boiler is operating under a steady load. Therefore, the combustion efficiency test does not
Get a quoteLet's assume a boiler working at pressure 5Bar and producing stea m of Two Tons per hour. Efficiency of this boiler is approx. 80%. What would be …
Get a quoteBR-GSG-500-10 : Boiler room with the Gas steam-generator 500kg/hr (max. 10bar) € 53925 excluding tax. Automatic gas steam-generator, available power 349 kW – from 250 up to 500 kg of hot steam per hour / up to 10bar. Regulation of the working steam pressure is adjustable in range from 1 to 10 bar. Compact design including the SPECK power unit.
Get a quoteBrand: J.G Equipamentos de Vapor Steam generator JG EG-16. heat Production-193,194 Kcal/h. Evaporation with water at 115 C-216 kg steam per hour. steam operation pressure 150 PSI-65a. fuel consumption. LPG Gas-14.00 kg/h natural Gas-17 m ³/h. Motor-0
Get a quoteFire Tube boiler is the simplest form of the internal furnace, vertical fire tube boiler. Fire tube boilers are a portable boiler and it requires a small floor space. The steam rating in fire tube boilers doesn't exceed 2500 kg per hour and pressure is limited to 10 bars.
Get a quote2500 kg/hour 11 bar Roučka Slatina Model VSK 2,5-1 Steam Boiler With Oil Burner Stock #HG62349 Used Roučka Slatina model VSK 2,5-1 steam boiler. Capacity 1250 – 2500 kg of steam per hour, max working pressure 1,1 MPa. Includes Weishaupt oil
Get a quote3.3. Make a rough estimate of the cost of steam per ton, produced from a packaged boiler. 10,000 kg per hour of steam are required at 15 bar. Natural gas will be used as the fuel, calorific value 39 MJ/m³ (roughly 1 MMBtu/1000 scf). Take the boiler efficiency as 80%.
Get a quoteCONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100 C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0 C to 100 C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350
Get a quoteSteam production: 37.5, 47 kg/h. Power: 350 W. Pressure: 10 bar. The Combijet JS D10 Steam Generator with Diesel Fuel Boiler – double Operator is ideal for heavier duty cleaning within the construction sector, at hotels, pools and even the pharmaceutical sector.
Get a quote2015/3/17 · 5.866 kJ/kg/K Saturated 1.00 Energy Flow 50,710 Boiler Blowdown Rate 3.3 % Boiler Energy 42,104 Combustion Efficiency 66.9 % Fuel Energy 62,935
Get a quote2. BOILERS Bureau of Energy Efficiency 27 Syllabus Boilers: Types, Combustion in boilers, Performances evaluation, Analysis of losses, Feed water treatment, Blow down, Energy conservation opportunities. 2.1 Introduction A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into
Get a quoteCONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100 C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0 C to 100 C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350
Get a quoteThe data were collected during a boiler trial for a duration of one hour: Pressure of steam = 9 .8 bar Temp. of steam leaving the superheater = 250 C Feed-water temperature = 25 C Calorific value of coal = 30,000 kJ/kg Quantity of coal burned per hour
Get a quoteStock number: UG6153 Second hand steam boiler by Clayton (Belgium) type EGKefid with working output of steam 157 kg/h at 10 bar pressure, and temperature 184C. Boiler is heated by natural gase. Gase consumption 11.7 Nm3/h. Coil has working volume 24 l
Get a quoteBrand: J.G Equipamentos de Vapor Steam generator JG EG-16. heat Production-193,194 Kcal/h. Evaporation with water at 115 C-216 kg steam per hour. steam operation pressure 150 PSI-65a. fuel consumption. LPG Gas-14.00 kg/h natural Gas-17 m ³/h. Motor-0
Get a quoteSolving for 'C', we get. C = 30161.14 kJ/kg ≈ 30160 kJ/kg. 11. A boiler is fired with fuel having calorific value 30000 kJ/kg. It produces steam at 5 bar. The dryness fraction of the steam generated 0.85. The efficiency of the boiler is 77% and the evaporative e capacity of the boiler is 10 kg of steam per kg of fuel.
Get a quoteA boiler has a 'from and at' rating of 2 000 kg/h and operates at 15 bar g. The feedwater temperature is 68°C. The use of Equation 3.5.1 will determine a factor to produce the same result: Note: These values are all from steam tables.
Get a quoteTranscribed image text: Q2/1 A boiler produces (2000 kg ) of dry and saturated steam per hours at (1Mpa). The feed water is heated by an economizer to a temperature of (110 C). The fuel feed rate is (225 kg/h) with having (30100 kJ/kg) of HV. If (10%) of fuel
Get a quoteboiler is low, i.e.9 tonne per hour Steam generation rate in water tube boiler is high i.e. 450 tonne per hour 4. For a given power the floor area required for steam generation
Get a quote(b) A Lancashire boiler generates 2400 kg of dry steam per hour at a pressure of 1 1 bar. The grate area is 3 m 2 and 90 kg of coal is burnt per m 2 of grate area per hour . The calorific value of coal is 33180 kJ/kg and the temperature of feed water is 17.5 o oC 3.
Get a quote2015/3/17 · 7.273 kJ/kg/K Phase Gas Energy Flow 30,746 Boiler Blowdown Rate 6.9 % Boiler Energy 27,536 Combustion Efficiency 90.6 % Fuel Energy 30,393 Blowdown Mass Flow 1.4 klb/hr Pressure 650.6 psig Sp. Enthalpy
Get a quoteFire Tube boiler is the simplest form of the internal furnace, vertical fire tube boiler. Fire tube boilers are a portable boiler and it requires a small floor space. The steam rating in fire tube boilers doesn't exceed 2500 kg per hour and pressure is limited to 10 bars.
Get a quote2010/12/13 · Conversion Factors. Multiply By To Get. BHP (Boiler Horsepower) 34.5 Lbs/Hr of Steam at 212°F. BHP (Boiler Horsepower) 0.069 GPM Water. BHP (Boiler Horsepower) 33,479 BTU/Hr. Lbs/Hr Steam 0.002 GPM Water. Lbs/Sq In 2.307 Feet of Water. Feet of Water (Head) 0.4335 Lbs/Sq In. Cubic Feet of Water 7.48 Gallons of Water.
Get a quote2017/1/7 · If the boiler produces 15000 kg of steam per hour at 24 bar from feed water of 40 C and the fuel consumption is 1650 kg/h, determine the condition of the steam produced. 8. A single-cylinder, the double-acting steam engine is 250mm bore by 300mm stroke and runs at 3. 5rev/s, steam is supplied at 1035 KN/m2 and the back pressure is 34 KN/m2 and the diagram …
Get a quote2021/3/11 · 90 tonnes per hour 250 tonnes per hour 450 tonnes per hour In a simple vertical boiler, the water tubes are: Vertical Horizontal Inclined None of these The diameter of the flue tubes of a Lancashire boiler is ____times that of shell. 0.2 0.4 0.6 0.8 0.2 0.4 0.8
Get a quoteSolving for 'C', we get. C = 30161.14 kJ/kg ≈ 30160 kJ/kg. 11. A boiler is fired with fuel having calorific value 30000 kJ/kg. It produces steam at 5 bar. The dryness fraction of the steam generated 0.85. The efficiency of the boiler is 77% and the evaporative e capacity of the boiler is 10 kg of steam per kg of fuel.
Get a quote2017/3/7 · Total wood savings cost (wood cost Rs 2500 per ton ) Quantity of steam generated per hour (Q) in kg/hr. . In a relatively small boiler, with a capacity of 10 MW, the radiation and unaccounted losses could amount to Industrial and Commercial Boilers – P2
Get a quoteA. 37,800 kg/hr B. 38,700 kg/hr C. 30,780 kg/hr D. 30,870 kg/hr The feed water to a boiler is 92% condensate and 8% make-up containing 270 ppm solids. What weights of solids enter the boiler per hour at 22,680 kg per steam evaporation?
Get a quoteThe data were collected during a boiler trial for a duration of one hour: Pressure of steam = 9 .8 bar Temp. of steam leaving the superheater = 250 C Feed-water temperature = 25 C Calorific value of coal = 30,000 kJ/kg Quantity of coal burned per hour
Get a quoteUsed Water Tube Package Boilers For Sale | Perry Videx
Get a quote